Model radiators and porous media

Bramble models a radiator core as a Darcy–Forchheimer porous region. You define it on the Template Case's Radiators tab, and Bramble can fit the coefficients from pressure-drop test data.

Before you start

  • Nothing needs enabling. The Radiators table is in Template Cases of the OpenFoam and OpenFoam with CHT Methodology Groups. Star-CCM+ Template Cases use Radiators (CCM) instead.
  • Decide how the core's upstream and downstream faces will be found (the Up/Down mode below), because it decides how you name the core zones.

Prepare the geometry

Each radiator needs a frame and a core. Use only letters, digits, _ and - in the radiator name.

  • Frame: a watertight solid round the core, so flow can't bypass it. Name it <zone>-<radiator name>, for example eb-rad-main or body-rad-water-lhs.
  • Core: the zones depend on the Up/Down mode:

    Up/Down Core zones Example for radiator rad-water-lhs
    Auto One zone, toint-<name>. Bramble finds the upstream and downstream faces itself toint-rad-water-lhs
    Manual Two zones: toint-<name>-up and toint-<name>-down, thin surfaces covering the whole core toint-rad-water-lhs-up, toint-rad-water-lhs-down
    Off One zone, toint-<name> toint-rad-water-lhs

For Manual, oversize the up and down faces by a few mm so they extend slightly into the frame and seal.

See toint zones.

Add a radiator

  1. In the Template Case editor, go to the Radiators tab. In Radiators, click New.
  2. Fill in the row:

    Field Enter
    Name The radiator name used in the zone names, for example rad-water-lhs
    Inside Point A point in the core, in metres (or mm if the editor is set to Use (mm)). Disabled for Auto, which works it out
    Darcy Coefficient, Forchheimer Coefficient The porous coefficients. Click the cog to fit them from test data
    Through Vector The unit normal to the core face, pointing with the flow
    Orthogonal Vector A unit vector across the face (usually right–left), orthogonal to the through vector. Three or four decimal places are enough
    Factors Multipliers on the coefficients in the through direction and the two directions across the core. The default 1, 10, 10 makes the resistance across the core ten times the through resistance
    Up/Down Off, Manual or Auto (see above)
    Export Exports a slice through the core after the run
    Fields The variables in the slice export

    For Auto, the vectors only need to be roughly aligned with the core. Bramble takes the flow direction from the vectors.

  3. Optionally, click Show Grid Settings to export a probe grid across the core: Grid Rows, Grid Columns, Grid Width (m), Height (m), Horizontal Edge (m) and Vertical Edge (m).

  4. Click Save, then Save in the header. If a field is wrong, the editor shows "Radiator Error: Radiator data must be filled in correctly".

When you save a radiator, Bramble adds monitors for it to Forces → Solve Monitors: the mass flow, and the area-weighted total pressure and pressure, on toint-<name> (or toint-<name>-up). For Manual, it also adds the pressures on toint-<name>-down.

Fit the coefficients from test data

  1. In the radiator row, click the cog next to Darcy Coefficient or Forchheimer Coefficient. Porous Data opens.
  2. In the Porous Data table, enter at least three test points, each a Velocity (m/s) and a dp (Pa). With fewer, the dialog shows "Enter a minimum of three porous data values" and Save stays disabled.
  3. In Porous Property, enter:
    • Thickness (m): the core depth along the through vector
    • Dynamic Viscosity (kg/m.s) and Density (kg/m3): the air properties at the test conditions
  4. Check the fitted curve and the Darcy Coefficient: and Forchheimer Coefficient: values, then click Save. Both coefficients are filled in.

Bramble fits dp = a₀ + a₁v + a₂v² to your points, then sets D = a₁ / (thickness × μ) and F = 2a₂ / (thickness × ρ).

Porous and fan jumps

For thin porous or fan surfaces that don't need a porous volume, use the Interior Zones tab instead:

  • Porous Jumps: Name (the zone), Permeability, Pressure Jump Co-efficient, Thickness, Max Velocity (m/s), Tags, Force Group
  • Fan Jumps: Name (the zone), Function (polynomial coefficients), Direction, Min Velocity and Max Velocity (m/s), Tags, Force Group

For heat rejection from a radiator, the Macro Heat Exchanger (the thermometer icon in the Radiators table) sets its air and coolant properties.

Check the set-up

Check Fails when
Radiator Coordinate System Orthogonality A radiator's through and orthogonal vectors aren't orthogonal
Radiator Coefficients D is outside 1e4–1e8, or F outside 1–10,000, for example "Porous region … does not have a sensible D coefficient (1e4 < D < 1e8)"
Check for unused or missing toints A radiator's toint zone is missing from the geometry, or a toint Part isn't used

To see each radiator, choose it in Select Pre-check Plots on the Run Checks tab. The Radiator Plots show the through vector in red and the normal vector in blue.

After the solve, Check Cell Zone Sizes flags a porous zone whose cell count differs from the baseline's by more than 10 %.

Related: Template Case editor reference · Zone naming · Checks reference · Configure pre-checks